Assessment3 min readBy Juan Manuel Rovira de Miguel
Hand dynamometer: how to choose one for your practice
Hydraulic, analogue or digital: what to look for when choosing a hand dynamometer to measure grip strength in clinical practice, physiotherapy or research.
Grip strength has become a basic measurement in geriatrics, clinical nutrition, physiotherapy and sports medicine. But not all dynamometers measure the same way, and a poor choice makes it harder to compare results with reference tables or between check-ups.
Types of dynamometer
| Type | How it measures | Advantages | Limitations |
|---|---|---|---|
| Hydraulic (Jamar type) | Pressure in an oil circuit, needle readout | Reference in most studies | Gives the peak only; manual reading; loses calibration over time |
| Analogue spring | Deformation of a spring | Cheap and light | Less precise; manual reading |
| Digital strain gauge | Electronic force sensor | Automatic reading, force-curve recording and data export | Agreement with the reference must be checked |
The hydraulic Jamar is the most widely used in studies, according to the review by Roberts et al. (2011), and many cut-off points were obtained with it or with similar devices.
What the evidence says: they are not interchangeable
A study from the University Hospital of León published in 2025 compared four dynamometers in 124 people: the hydraulic Jamar as reference, two electronic devices and one analogue. Correlations with the Jamar were very high, but there were systematic differences in values and insufficient agreement. In patients, means ranged from 25.7 kg with one device to 29.6 kg with another.
Two practical consequences:
- Always use the same dynamometer to follow up a person.
- Be careful when applying cut-off points, such as the 27 and 16 kg of the European sarcopenia consensus, if they were obtained with a different device from yours.
What to look for when choosing
- Accuracy and resolution. Look for 0.1 kg resolution and test-retest reliability data.
- Adjustable handle. Grip changes with hand size; the standard protocol adjusts the handle to each person.
- Automatic recording. Avoids errors when reading and writing down values, and stores the patient’s history.
- Force curve, not just the peak. Time to peak force and how quickly force develops (RFD) provide information the peak does not, especially in older adults. We explain it in RFD and ageing.
- Comparison between hands. To detect asymmetries after an injury or surgery.
- Data export. Essential in research and useful for clinical reports.
- Comfort. A handle that does not hurt allows true maximal efforts, especially in people with osteoarthritis.
How to measure properly, whatever the device
Always follow the same protocol: person seated, elbow at 90°, wrist neutral, three alternating attempts per hand and the best value. You will find the details and the table of values by age in grip strength: normal values.
Tratech HandGrip
HandGrip is a portable digital dynamometer with 0.1 kg precision and a 320 Hz sampling rate. It shows maximal force, the force curve and RFD in real time, compares both hands and exports data to Excel and CSV. It weighs 220 g and has 6 hours of battery life.
Frequently asked questions
What types of hand dynamometer are there?
The hydraulic (Jamar type) gives only the peak force; the analogue spring type is cheap but less precise; and the digital strain-gauge type records the full force curve and allows data export.
Can results from different dynamometers be compared?
Not directly. A 2025 study with 124 people found systematic differences between four dynamometers: means ranged from 25.7 to 29.6 kg. To follow up a person, always use the same device.
What should a good dynamometer for clinical practice have?
0.1 kg resolution, test-retest reliability data, an adjustable handle, automatic recording, a force curve with RFD, comparison between hands and data export.
What is the protocol for measuring grip strength?
Person seated, elbow at 90° and wrist neutral; three alternating attempts per hand, taking the best value.
References
- García Sastre D et al. Dinamometría de mano: ¿importa el dispositivo? [Hand dynamometry: does the device matter?] Endocrinología, Diabetes y Nutrición, 2025.
- Roberts HC et al. A review of the measurement of grip strength in clinical and epidemiological studies. Age and Ageing, 2011.
- Cruz-Jentoft AJ et al. Sarcopenia: revised European consensus on definition and diagnosis. Age and Ageing, 2019.